Total Viable Count Method

Total Viable Count is used to calculate the microbial load (CFU/mL) of a given sample. Learn how to perform the total viable count method here.
Total Viable Count is a microbiology calculation used across many industries to determine the microbial load of a substance. Using this method, scientists can quantify the amount of living (viable) bacteria in a sample. This is a critical lab technique for public safety.
Scientists can perform the total viable count method for liquids and solids. Liquid samples can be processed and tested as is, while solid samples are swabbed. The swab is then released into a sterile phosphate buffer, where the solution can be processed and tested.
The total viable count method is used in environmental, food science, medical settings and more. Chemical Engineers may use it to test the quality of drinking water. Food Scientists may use it to ensure the microbes in dairy products don’t exceed specified limits. Pharmaceutical Scientists may use it to ensure their ‘sterile’ clean room is in fact microbial free.
Microbiology techniques such as these are central to consumer safety. Learn more about the total viable count method (also known as the aerobic and total plate count method) below, including lab test and calculation examples!
Total Viable Count
What is the Total Viable Count Method?
The Total Viable Count Method quantifies the amount of living bacteria inside a sample. This sample can be collected from a liquid solution or a swab that has been released into a phosphate buffer.
It is important to note that the total viable count may be known by other names, such as total plate count, aerobic plate count or standard plate count. All of these terms are laboratory techniques that quantify living (viable) microbes. They may differ in methodology only slightly (ex: techniques for aerobic vs anaerobic bacteria).
Quantifying bacteria is an essential laboratory skill. As microbes cannot be seen by the naked human eye, scientists rely on such techniques to keep consumers safe.
Methods like the total viable count can test water, food products, medications and more. The colony forming units (CFUs) can then be compared to applicable standards to determine if the microbial load is acceptable. See an example of the total viable calculation below.
Total Viable Count Calculation

Let’s say a Laboratory Food Scientist wants to test the microbial load of milk.
Milk undergoes the pasteurization process to kill bacteria. If microbes like P. aeruginosa are present in milk, it could cause illness and deteriorate the milk during storage.
After pasteurization, it is critical for scientists to test the milk, ensuring it is germ free.
The total viable count method will quantify bacteria like P. aeruginosa that may be present in the milk.
Image 1 shows a milk sample that underwent a serial dilution. The milk sample was 10 mL total. 1 mL of the milk sample was added to 9 mL of sterile water, resulting in a 10 fold (10-1) dilution. 1 mL of the 10-1 sample was added to 9 mL of sterile water, resulting in a 100 fold (10-2) dilution.
1 mL of each diluted sample was plated and incubated on a milk agar dish. This fosters a good growth environment for any dairy bound microbes.
After 36 hours of incubation, the food scientist can complete the total viable count. Colonies must be between 30 and 300 to analyze the dish for total viable count.
They saw that the 10-2 sample was too few to count (TFTC). The 10-1 sample was not too numerous to count (TNTC) or TFTC.
Thus, the total viable count could be calculated as such:
Colony Forming Units (CFUs) = # of colonies x dilution factor (df) / volume of sample plated
CFUs = 33 X 101 / 1.0 mL
= 330 CFUs / mL
*Note that the dilution factor is the reciprocal of the tube dilution (10-1 vs 101).
Total Viable Count Procedure Example

Here is an example for a total viable count experiment:
This procedure demonstrates how the total viable count method may be used to quantify P. aeruginosa. This is a degrading microbe that can cause illness if left to enumerate in milk in large quantities.
- Prepare 100 mL of sterile milk agar in an Erlenmeyer flask and maintain it in a ~ 55℃ water bath.
- Label 4 petri dishes with your initials, date, study name and each, respectively: (1A 10-1 ), (1B 10-1) and ( 2A 10-2), (2B 10-2).
- Collect 10 mL of pasteurized milk to be used as the stock test sample.
- Collect 2 water blank tubes, with 9 mL of sterile water each. Label them 10-1 and 10-2, respectively.
- Invert the 10 mL test sample 5 times to ensure proper dispersion of any microbes.
- Using a sterile tip and pipette, transfer 1 mL of the 10 mL milk sample to the water blank tube labeled 10-1. Discard the pipette tip. Mix the tube by inverting.
- Using a sterile tip and pipette, transfer 1 mL from the tube labeled 10-1 and transfer to the water blank tube labeled 10-2. Discard the pipette tip. Mix the tube by inverting.
- Invert the 10-1 test tube to mix, and add 1 mL of the solution to the 1A and 1B petri dishes, respectively.
- Invert the 10-2 test tube to mix, and add 1 mL of the solution to the 2A and 2B petri dishes, respectively.
- Add 10 mL of melted and cooled milk agar to each respective petri dish.
- Swirl the plates to properly disperse the sample and allow them to sit for solidification.
- Incubate plates inverted for 36 hours at 40℃.
Total Viable Count Data Analysis: After incubation, quantify the microbial load using the equation in Image 1. Choose plates that have colonies between 30 – 300 colonies (not TFTC or TNTC). Calculate the total viable count for both trials of the chosen dilution plate to get an average (most accurate).
Note: Scientists will compare the CFU/mL count to regulatory standards. In this case, for instance, the food scientist may be looking that the milk is less than 20,000 CFU / mL, as that is the noted acceptability of Grade A pasteurized milk.
Why is the Total Viable Count Method Used?
The total viable count method is used to quantify the microbial load of a substance, compare that load against applicable standards, and ultimately, keep consumers safe.
Microbes may be present in drinking water, food, drugs, work spaces and other places. Since bacteria cannot be visualized by the naked human eye, scientists rely on these scientific methods.
Using the total viable count method (also known as total plate count), scientists can quantify the germs in a sample. This can then be compared to regulatory standards (ex: Environmental Protection Agency Drinking Water Standards).
Ultimately, this testing and compliance to regulatory standards keeps consumers safe. Without methods like the total viable count, we would be at greater risk of severe public health outbreaks.
Conclusion

In conclusion, the Total Viable Count Method is a microbiology technique used to calculate the microbial load (CFU/mL) in a given sample.
The total viable count method can be performed on liquid and solid samples. Liquid samples, like vaccine diluents, water and milk, are tested as is. Solid sample will be swabbed, and that swab will be inoculated into a sterile phosphate buffer to release any microbes and test the solution.
Scientists perform methods such as this one because microbes cannot be seen by the naked human eye. Thus, it is critical to use scientific testing to identify them.
Overall, the total viable count method (also known as the aerobic plate count and total plate count) keeps consumers safe from germs that could be festering inside of products.
Next Steps
We hope this article has helped you learn more about the Total Viable Count Method.
At My Life Science Career, we are dedicated to being the #1 scientific resource site for professionals and students. We publish articles on laboratory skills, engineering principles and more, to assist you in developing and maintaining your dream science career.
Want to be a part of our growing, STEM-minded community? Be sure to connect with us on LinkedIn, Twitter, Pinterest and Instagram. Also, don’t forget to take our FREE science career quiz to see which science career is best for you!
Subscribe To Our Newsletter For More Free Science Tips!
Similar Reads
- Code White Hospital Meaning - November 10, 2026
- Code Pink Hospital Meaning - November 3, 2026
- Code Purple Hospital Meaning - October 27, 2026