Spread Plate Method

The Spread Plate Method is a basic microbiology technique that is used to distribute a sample over an agarose gel. Learn how to do it, here.
The Spread Plate Method is a laboratory technique used to disperse a bacterial or cell sample across the face of an agar plate. Microbiologists commonly perform this method to harvest cell cultures, quantify the colony forming units in a sample (CFUs/mL), perform medical testing and much more.
Performing the spread plate method involves good sterilization skills. For proper identification of microbes, the sterile spreader used must be free from outside contamination. Thus, a Bunsen burner and ethanol are used to ensure sterility of the tool.
Students can expect to learn the spread plate method in their first microbiology laboratory course. As this skill will have endless downstream applications, learning it is vital for scientists. Learn more about the spread plate method, how to perform it, and real life applications of it, below.
Spread Plate Method
What is the Spread Plate Method?
The Spread Plate Method is a biology laboratory technique used to evenly disperse a sample over an agarose gel plate. It is most commonly used in microbiology experiments (ex: examining microbial growth or harvesting bacteria for research).
Scientists employ the spread plate method on a daily basis in the laboratory. It is one of the most fundamental laboratory techniques a scientist will learn, alongside pipetting and serial diluting.
For example, an academic researcher studying S.aureus may plate the bacteria using the spread plate method. The bacteria can later be quantified using the total plate count and similar methods. An environmental chemist may conduct spread plating in a laboratory to test for mold in a sample from a home.
The spread plate technique allows bacteria to be separated so individual colonies can be observed. This is incredibly important for the characterization and accurate identification of microbes.
Undergraduate science students should expect to conduct the spread plate method in their first microbiology laboratory course. See how it is performed in the following section.
How to do the Spread Plate Method

Performing the Spread Plate Method is a mostly straightforward technique, however, proper sterilization steps must be followed.
Sterilization protects the sample to be tested against contamination. If the sample were to be contaminated, it could give a scientist a false reading.
The following components are needed to perform the spread plate method: a liquid sample to be tested, an agarose petri dish, a micropipette/tip, a Bunsen burner, an ethanol solution and a laboratory spreader tool (cell spreader).
First, the laboratory spreader should be dipped in ethanol, a known disinfectant. It is most important for the bended or triangular section of the spreader to be fully immersed in the ethanol.
Next, the sample to be tested is added to the agar face of the petri dish. Do this simply by removing the top of the petri dish, and pipetting the sample onto the agar. Replace the lid afterwards to avoid any contamination from air particles.
Then, remove the spreader from the ethanol and pass it through a Bunsen burner flame. This both dries the alcohol and further sterilizes the tool. After flaming, allow the spreader to cool without touching any other surface.
Lastly, use the cooled sterile spreader to evenly distribute the sample solution across the agar’s surface. Some laboratories employ a lab turn table or Lazy Susan to spin the petri dishes so the sample is equally spread.
Some scientists may also spin the dish with one hand, while spreading with the other. For many, spinning isn’t necessary at all. This will depend on the skillset of the scientist and the experiment at hand. Regardless of the chosen technique, an even distribution is most important.
Afterwards, scientists can incubate the plate under specific conditions (ex: 38℃ for 24 hours). Incubation guidelines vary depending on bacteria types (ex: anaerobic vs aerobic).
After incubation, scientists can perform the total plate count method, characterize the microbial colonies, compare growth to other incubation types or any other necessary research.
Examples of the Spread Plate Method

Looking to contextualize when the spread plating technique would be used? Knowing real life applications of laboratory methods is always helpful. See just two examples (out of dozens that could be listed) of when a scientist may employ the spread plate method.
Urinalysis
Urinalysis refers to laboratory testing done on urine (pee) samples. Laboratory testing on urine can identify UTIs, diabetes, presence of narcotics and more. The spread plate method helps do this.
A medical laboratory scientist may perform a urinalysis to test a patient for a UTI. They will plate a urine sample on an agar plate and perform the spread plate method. After incubation, if bacteria (ex: E. coli) are found in large numbers, the patient may be diagnosed with a UTI and prescribed antibiotics to clear it.
Antibiotics
Antibiotics work to kill bacteria that cause infections and make patients ill. The spread plate method is vital to antibiotic research.
For instance, S. pneumoniae is a bacteria known to cause ear infections in humans. Antibiotic research involves plating S. pneumoniae using the spread plate method and observing its response to different agents. The antibiotic, moxifloxacin, for example, has been shown to stop its growth.
Conclusion
In summary, the Spread Plate Method is one of the most fundamental microbial methods a scientist will use. Spread plating is done by pipetting a bacterial sample onto a petri dish with good growth media (solid agar) and spreading the sample throughout for dispersed growth.
One of the most important principles to remember for the spread plate technique is sterilization. The spreader must be free of outside bacteria, as its presence would cause contamination and false readings to scientists. Thus, ethyl alcohol and flaming are used to kill any outside microbes.
The downstream applications of the spread plate method are endless. It is foundational to all academic research that leads to vaccines, medications, environmental solutions and more.
Entry level scientists can expect to learn the spread plate method in undergraduate, and apply it throughout their schooling and career.
Next Steps
We hope this article has helped you learn how to perform the Spread Plate Method!
At My Life Science Career, we are committed to being your #1 informational source for your life science career needs. We serve as a resource site for science students and scientists. We post scholarships, create STEM career quizzes (FREE to take), post science career articles and so much more, to help scientists build and maintain careers they love.
Do you want to be a part of our growing, STEM-minded community? Be sure to connect with us on LinkedIn, Twitter, Pinterest and Instagram, for daily science articles. Also, be sure to SHARE this article using the buttons at the top and bottom of the screen to help another scientist. Lastly, we love interacting with our readers. Leave us a comment below to spark scientific discussion!
Subscribe To Our Newsletter For More Free Science Tips!
Similar Reads
- Code White Hospital Meaning - November 10, 2026
- Code Pink Hospital Meaning - November 3, 2026
- Code Purple Hospital Meaning - October 27, 2026
