Pour Plate Method

The Pour Plate Method combines a liquid sample and liquid agar to form a gel and detect microbes. See how to perform it, here.
The Pour Plate Method is a commonly used laboratory technique for microbiologists. This procedure involves swirling a liquid bacteria sample and liquid agarose growth media, in a petri dish. The sample then forms into a gel, which is incubated. Afterwards, scientists can study microbial properties such as growth patterns, identify bacterial strains, harvest cultures, quantify colonies and more downstream applications.
A scientist may choose to perform the pour plate method, as opposed to the streak plate method or spread plate method, for several reasons. The pour plate method allows for both anaerobic and aerobic growth. A larger volume of sample can also be tested, as opposed to methods limited to only the agar’s surface.
Performing the pour plate method is a skill all scientists should know. Learn more about this method, when it is used, and how to perform it, below.
Pour Plate Method
What is the Pour Plate Method?
The Pour Plate Method is a technique used in microbiology laboratories to identify bacteria that may be inside of a sample.
Inside a petri dish, a liquid sample is mixed with liquid agarose and left to solidify, becoming a gel. The petri dish is then incubated. After incubation, scientists can examine bacterial growth in and on top of the gel.
Scientists use the pour plate method for various sample types. Liquid samples, like water, common solvents, and milk can be tested as is. Solid samples, like food and drug tablets, are blended into sterile water so the solution can be tested.
The pour plate technique is vital to microbial limit and bioburden testing. Different industries, such as pharmacology, will have guidelines for the pour plate technique. Ultimately, the method helps keep consumers safe by identifying contaminants in products.
It is important for scientists to know when the pour plate method should be used, instead of the spread plate method or streak plate method. Details for when the pour plate method should be used are explained below.
When is the Pour Plate Method Used?

Pour Plate vs Spread Plate vs Streak Plate
The pour plate method, spread plate method and streak plate method are all common microbiology techniques used to enumerate bacterial colonies. Each one has settings they are best suited for.
The spread plate method is best used for aerobic bacteria, and plating smaller volumes of liquid (ex: .1 mL). This is because less surface area is used, in comparison to the pour plate method, which allows growth both inside and on top of the agarose gel.
The streak plate method is best used when discrete colonies are desired by a scientist. It is great for studying the morphology of microbes (ex: color, elevation, shape) in confluent and isolated growth.
When to choose the pour plate method
The pour plate method is most suitable for plating larger sample volumes and detecting both anaerobic and aerobic bacteria.
When conducting the pour plate technique, the sample to be tested and liquid agarose are swirled together to create a gel. This allows a larger volume of sample to be tested, as compared to the spread plate method, which is limited to the agar’s face surface area.
Scientists may desire to test a larger volume of sample if its microbial load is low. When microbial loads are low, this leads to colony forming units being too few to count (TFTC), thus, unquantifiable for scientists. This is explained in more detail in the Total Plate Count Method.
Additionally, the pour plate method is better suited for testing both anaerobic and aerobic bacteria. The streak plate and spread plate methods plate on top of the agar’s face, allowing the microbes to be exposed to oxygen.
Although that oxygen can be limited using anaerobic incubation, those conditions would kill aerobic bacteria.
The pour plate method allows an environment for both bacteria types. Anaerobic bacteria (grow without oxygen) can enumerate within the agarose gel. Aerobic bacteria (need oxygen to grow) can enumerate on top of the agar’s face, where it is exposed to oxygen.
These are the factors scientists consider when choosing the pour plate method, as opposed to others.
How to do the Pour Plate Method

Pour Plate Method Explained
To perform the pour plate method, start with a sample that has undergone a serial dilution and agarose gel that has been melted, cooled and maintained in a liquid state (using an autoclave or water bath).
Pipette one of the serial diluted samples onto a sterile petri dish (ex: 1 mL). Add the cooled agar to the dish (ex: 15 mL) and replace the sterile petri dish lid. Swirl the plate to evenly distribute the sample and agarose.
Once evenly mixed, allow the solution to solidify into a gel. Afterwards, incubate the plates in inverted positions (lid down) at specified temperatures (ex: 40°C for 24 hours).
Pour Plate Method Example
A scientist may perform the pour plate method when they want to test water used in pharmaceutical manufacturing.
Different grades of water are used for varying wet bench activities, and the pour plate method can help ensure each type meets its microbial load specifications.
To test, the scientist may collect 10 mL of a Water For Injection sample. This type of quality water is used to deliver patients medications/injections and is governed by the USP.
This water sample will undergo a serial dilution by adding 1 mL of it to 9 mL of sterile water in a test tube (10-1). 1 mL of the 10-1 sample is added to 9 mL of sterile water (10-2). This continues so forth, according to the experiment’s dilution needs. The samples are mixed well for equal distribution.
A liquid agarose solution will be prepared by melting solid agar. This could be done in a flask, or, individual sterile agar deep tubes can be liquified using an autoclave or microwave.
Afterwards, the liquid agar is maintained at a standard temperature of 45°C using a water bath. The agar must be cooled so as to not kill any potential microbes.
Now, the pour plate method can be performed. A volume of the solution (ex: 100 uL, 1 mL) is plated onto a sterile petri dish. A volume of cooled liquid agar is added to the petri dish (ex: 15 mL, 20 mL). The dish is then swirled to mix the sample and agar together, evenly.
The solution is left to solidify into a gel. Then, the plate is incubated. Afterwards, scientists can perform the total plate count, or similar methods (see aerobic, anaerobic) to quantify the CFUs / mL of the Water For Injection.
Conclusion

In summary, the Pour Plate Method is a microbiology technique used to equally distribute a liquid sample throughout a gel. The gel is left to enumerate and the microbial load (germs) inside the sample can be quantified using the total plate count and like methods.
The pour plate method has vast industrial applications. Food scientists use it to test fruits, vegetables and meats for bacteria. Pharmaceutical scientists perform pour plating to test for contaminants in medical solvents. Chemical engineers may apply its principles to test for contaminants in drinking water. Academic researchers may use it to study growth patterns of bacteria.
For scientists, the pour plate method is a must know technique. With is broad usage in the science industry, it is worth reviewing for science students and professionals.
Next Steps
We hope this article has helped you learn more about the Pour Plate Method!
At My Life Science Career, we are dedicated to being your #1 informational site for science and life science engineering tips. We provide our readers with FREE career quizzes, engineering and laboratory skill reviews and more, to help them develop careers they love.
Do you want to be a part of our growing, STEM-minded community? Be sure to connect with us on LinkedIn, Twitter, Instagram and Pinterest, where we post daily science/engineering articles. Also, leave us a comment below and share this article (using the buttons at the top and bottom) to help another scientist!