Anaerobic Plate Count Method

Anaerobic Plate Count is a microbiology method used to quantify non-oxygen dependent bacteria in a sample. See how to perform it, here.
Anaerobic Plate Count is a skillful technique, used to quantify viable anaerobes in a sample. Anaerobes are bacteria that do not need oxygen to grow and survive. They are mainly present in soil. However, if present in drinking water, food or medications, they could be harmful to consumers.
To prevent their unintended presence, scientists rely on the anaerobic plate count method. This technique starts by collecting a sample (ex: blood or saliva from a patient, drinking water, soil) and performing a serial dilution. The samples can then be plated on agar dishes and incubated in deoxygenated environments.
Afterwards, scientists can conduct the anaerobic plate count. This is a formula that gives the colony forming units (CFUs) per mL of a sample. Learn more about this technique with example calculations, applications and an example procedure, below!
Disclaimer: Contained in this post are affiliate links. This means that if you make a purchase through a link, I may receive slight compensation from the affiliate at no cost to you.
Anaerobic Plate Count
What is the Anaerobic Plate Count?
The Anaerobic Plate Count Method is a microbiology technique used to quantify the amount of living (viable) non-oxygen dependent bacteria, or anaerobes, in a sample.
Scientists look to identify, amplify and study anaerobes for many purposes. A common anaerobe, C.sporogenes, was found to kill cancerous colon tumor cells. Anaerobes are also vital to the bioaugmentation process, a natural way of degrading waste in water. With these benefits, anaerobes are of great interest for upstream researchers.
It is important to note that there are different types of bacteria. Anaerobes thrive in nonoxygenated environments. Aerobes thrive in oxygen rich environments. Facultative anaerobes thrive in both. With these differences, scientists have developed different techniques for their growth and study.
For the anaerobic plate count, the bacteria must have a deoxygenated environment for growth. Below, we will discuss how scientists create this environment and how they quantify the bacteria using the anaerobic plate count.
Anaerobic Incubation Techniques

To complete the anaerobic plate count, scientists must first create a deoxygenated environment for anaerobic enumeration. This process involves creating a CO2 (carbon dioxide) rich, vacuum sealed space for the microbes. There are two common ways of creating this environment – in a sealed jar or in a chamber.
Anaerobic Plate Count Incubation Using a Jar
The anaerobic jar method is a common technique for scientists. Brands like the BD Gaspak and others have created commercially available jar kits for this method.
It works by tightly sealing the jar with a screw clamp. This excludes oxygen and creates a nonreducing medium for incubation.
A hydrogen generator pack is included with the system. Once water is added, the foil packet generates hydrogen and CO2. The palladium catalyst / holder in the system then uses the hydrogen and residual oxygen to create water.
With the residual oxygen turned to water, the environment is now CO2 rich. Furthermore, scientists can validate the presence of CO2 with a strip that is included with the apparatus. Inside the jar, this strip will turn from blue to colorless in a deoxygenated environment.
The petri dishes are put inside the jar, for all the above activity to ensue. They are incubated at ideal temperatures. Then, scientists can quantify growth using the anaerobic plate count.
Anaerobic Plate Count Incubation Using a Chamber
Chambers, or anaerobic incubators, follow the same scientific principles. Industrial equipment like these are ideal for laboratories frequently conducting the anaerobic plate count.
The plated, anaerobic petri dishes are incubated inside a deoxygenated chamber. A vacuum pump is employed to create an airtight, sealed environment, limiting oxygen.
Hydrogen gas is added to the system to react with trace / excess oxygen. The chemical element, palladium, is used as a catalyst to combine the hydrogen gas and oxygen, as this combination is not naturally occurring. Water is then formed.
With the trace oxygen turned to water, the environment is now deoxygenated. Similarly with the jars, indication paper is included to let scientists know the oxygen status of the chamber.
After incubation at ideal temperatures and time, scientists can remove the petri dishes. They can then perform the anaerobic plate count calculation in the following section.
Anaerobic Plate Count Calculation

Let’s say a clinical laboratory is testing the blood sample of a sepsis patient.
Bacteria, like the anaerobe C.sporogenes, are known to cause sepsis, an infection complication caused by harmful microbes. Symptoms may include dizziness, shortness of breath and other adversaries.
Doctors who believe a patient may be encountering sepsis will collect blood and urine samples for lab testing. The scientists will perform the anaerobic plate count to see if anaerobes like C.sporogenes are present. This is necessary for the diagnostic and treatment process.
In the Image 1 example, the team began with a 10 mL patient blood sample. This sample then underwent a serial dilution.
1 mL of the 10 mL blood sample was added to 9 mL of sterile water (10-1). 1 mL of the 10-1 sample was added to 9 mL of sterile water (10-2). 1 mL of the 10-2 sample was added to 9 mL of sterile water (10-3).
To perform the anaerobic plate count, 1 mL of each sample was plated onto separate petri dishes with good growth media, and underwent anaerobic incubation for 48 hours at 38℃.
The colonies on the dish must be between 30 and 300 to calculate anaerobic plate count. The clinical lab saw that the only plate that was not too numerous to count (TNTC) or too few to count (TFTC) was the 10-1 plate.
Using The 10-1 Plate, The Team Calculated The Anaerobic Plate Count As Such:
Colony Forming Units (CFUs) = # of colonies x dilution factor (df) / volume of sample plated
CFUs = 72 X 101 / 1.0 mL
= 720 CFUs / mL
*Note that the dilution factor is the reciprocal of the tube dilution (10-1 vs 101).
Anaerobic Plate Count Example Procedure

Here Is An Example Procedure For An Anaerobic Plate Count Experiment:
This procedure demonstrates how the anaerobic plate count method can be used to quantify anaerobes in a patient’s blood sample.
Plating for the Anaerobic Plate Count
- Collect 10 mL of blood from the patient.
- Collect 6 Trypticase Soy Agar plates (TSA plates) and label them each, respectively; 1A 10-1, 1B 10-1, 2A 10-2, 2B 10-2, 3A 10-3 and 3B 10-1. Include any other necessary labeling info.
- Collect 3 blank test tubes with 9 mL of sterile water in each. Label each, respectively, 10-1, 10-2, and 10-3.
- Using a sterile tip and pipette, transfer 1 mL of the blood sample to the water blank tube labeled 10-1. Discard the pipette tip. Mix the tube (by lightly shaking/inverting).
- Using a sterile tip and pipette, transfer 1 mL of the 10-1 sample to the water blank tube labeled 10-2. Discard the pipette tip. Mix the tube (by lightly shaking/inverting).
- Using a sterile tip and pipette, transfer 1 mL of the 10-2 sample to the water blank tube labeled 10-3. Discard the pipette tip. Mix the tube (by lightly shaking/inverting).
- Pipette 1 mL of the 10-1 dilution on the 1A 10-1 and 1B 10-1 TSA plates, respectively. Repeat the same process for the 10-2 and 10-3 dilutions and labeled plates.
- Using a sterile spreader (dipped in ethanol, passed through Bunsen burner and cooled), disperse the 1 mL sample on each plate over the gel surface (see Spread Plate Method here).
- Allow plates to sit facing up (lid up, gel down).
Incubation for the Anaerobic Plate Count
- Collect a GasPak Anaerobic Apparatus Jar.
- Tear open the hydrogen/CO2 packet and place it in the jar.
- Place the petri dishes inside the jar, in an inverted position.
- Take the indicator strip and place it inside the jar so that it is easily readable.
- Add ~10 mL of water to the hydrogen/CO2 packet. Quickly seal the jar with the gasket and screw clamp top.
- Incubate for 48 hours at 38℃
Anaerobic Plate Count Data Analysis: After incubation, quantify the microbial load using the equation in Image 1. Choose plates that have colonies between 30 – 300 colonies (not TFTC or TNTC). Calculate the anaerobic plate count for both trials of the chosen dilution plate to get an average (most accurate).
Conclusion
In summary, the Anaerobic Plate Count Method is a laboratory technique used to quantify non-oxygen dependent microbes (anaerobes) in a sample.
A special apparatus is needed to create a deoxygenated environment for the bacteria to grow. Scientist do this by using a chamber/incubator or the jar method. The bacteria can be left to grow and enumerate. Afterwards, scientists can use the anaerobic plate count equation in Image 1 to quantify the microbes.
The anaerobic plate count method has vast usage. Medical scientists may use it to detect and quantify harmful bacteria in a patients sample (ex: saliva, blood). Environmental scientists may use it to ensure anaerobes that cause illness aren’t present in drinking water.
As bacteria cannot be seen with the naked human eye, scientists rely on laboratory techniques such as the anaerobic plate count. It is a skill all scientists should be familiar with.
Next Steps
We hope this article has helped you learn more about the Anaerobic Plate Count Method!
At My Life Science Career, we are committed to being the #1 Informational Resource Site for scientists and students. We help our readers develop and maintain their science careers in a holistic way. We provide FREE science career quizzes, conduct career reviews, post lab/engineering skill reviews and so much more!
Do you want to be a part of our growing, STEM-minded community? Connect with us on LinkedIn, Twitter, Instagram and Pinterest. Don’t forget to SHARE this article using the buttons at the top and bottom of the article, and leave us a comment if we helped you!
Subscribe To Our Newsletter For More Free Science Tips!
Similar Reads
- Code White Hospital Meaning - November 10, 2026
- Code Pink Hospital Meaning - November 3, 2026
- Code Purple Hospital Meaning - October 27, 2026