Aerobic Plate Count Method

Aerobic plate count is a microbiology technique used to quantify the aerobes (oxygen dependent bacteria) in a sample. Learn about it here.
Aerobic Plate Count is a scientific calculation which tells how many microbes are in a sample. The method is specific for aerobic bacteria, which need oxygen to survive, grow and thrive.
To perform the aerobic plate count method, scientists first collect a sample to be tested. This could be a bacterial sample from a patient, a swab from a hospital operating room, filtered water that needs to be assessed or more.
The sample is then diluted (and if a swab, suspended in a solution prior) and plated onto an agarose petri dish. The oxygen rich environment allows the aerobes to grow.
Afterwards, scientists can quantify the microbes using the aerobic plate count. They will count a dish that has between 30 to 300 colony forming units (CFUs). They will then perform the aerobic plate count formula : (# of colonies x dilution factor) / (volume of solution plated). This CFU / mL calculation can then be compared to acceptable standards.
Aerobic plate count ultimately aids in public safety, disease detection and biological research. See examples of calculations, procedures and uses, below.
Aerobic Plate Count
What is the aerobic Plate Count Method?
The aerobic plate count method is a quantitative microbial technique used to calculate the amount of bacteria in a sample. It may also be referred to as the total plate count method. The two mirror each other in methodology, however, the aerobic plate count method is specific for aerobic (oxygen dependent) bacteria.
Two main classifications of bacteria exist; aerobic and anaerobic. Aerobic bacteria grow and thrive in oxygen rich environments. Without it, the bacteria will not survive (will not be viable). Oppositely, anaerobic bacteria thrive in CO2/deoxygenated environments. They have adapted to grow without oxygen.
As the name implies, the aerobic plate count method is used for the quantification of aerobes (oxygen required microbes). Most bacteria found on commonly touched household, school and workplace items are aerobic, making the aerobic plate count method critical.
To perform this testing method, scientists will collect a sample (ex: swab) and process it accordingly. After petri dish incubation, the viable colonies or colony forming units (CFUs) can be counted.
Performing calculations for the aerobic plate count method will be based on the sample’s dilution factor. See an example of how to calculate it below.
aerobic Plate Count Calculation

Let’s say a pharmaceutical cleanroom wants to have their sanitation validated by a microbiology lab.
To do so, engineers at the pharmaceutical company will rub swabs against applicable items in the cleanroom. They will then send the swabs to a microbiology company that performs the aerobic plate count method.
The aerobic plate count method will identify aerobes, such as M. luteus, that may be present in the cleanroom.
Microbiologists will inoculate each swab into a solution, serving as the stock sample. In this example, a microbiologist performs 10 fold (10-1), 100 fold (10-2), 1000 fold (10-3) and 10000 fold (10-4) dilutions on the sample. This is known as a serial dilution.
The dilution for the aerobic plate count will go as follows: 1 mL of the sample to 9 mL of sterile water (10-1) , 1 mL of the 10-1 sample to 9 mL of sterile water (10-2) , 1 mL of the 10-2 sample to 9 mL of sterile water (10-3), and 1 mL of the 10-3 sample to 9 mL of sterile water (10-4).
For the aerobic plate count method, 1 mL of each sample was plated onto separate agarose petri dishes and incubated in an inverted position for 48 hours at 37℃.
To calculate aerobic plate count, the colonies on the dish must be between 30 and 300. The microbiologist saw that the 10-1 and 10-2 plates were too numerous to count (TNTC) and the 10-4 was too few to count (TFTC). But the 10-3 or 1000 fold dilution had colonies in line (ex: 56 colonies).
Using the 10-3 plate, the microbiologist calculated the aerobic plate count as such:
Colony Forming Units (CFUs) = # of colonies x dilution factor (df) / volume of sample plated
CFUs = 56 X 103 / 1.0 mL
= 56000 CFUs / mL
*Note that the dilution factor is the reciprocal of the tube dilution (10-3 vs 103).
aerobic Plate Count Procedure Example

Here is an example procedure for an aerobic plate count experiment:
This procedure demonstrates how the aerobic plate count method can be used to detect and quantify aerobes like M. luteus. A pharmaceutical, sterile cleanroom may send swabs to a microbiology lab to ensure their environment is germ free.
- Inoculate the swab sample into 10 mL of sterile phosphate buffer (allows for any microbes to be released into the solution and their integrity to stay viable). This will be the stock sample.
- Liquefy ~100 mL of agarose gel by boiling or autoclaving. Cool in an ice bath at ~45℃ .
- Label 6 petri dishes with your initials, date, study name and each, respectively: (1A 10-1 ), (1B 10-1), ( 2A 10-2), (2B 10-2), (3A 10-3 ) and (3B 10-3 ).
- Collect 3 water blank tubes, with 9 mL of sterile water each. Label them 10-1 , 10-2, and 10-3 , respectively.
- Invert the 10 mL stock sample 5 times to ensure proper dispersion of any microbes.
- Using a sterile tip and pipette, transfer 1 mL of the 10 mL stock sample to the water blank tube labeled 10-1. Discard the pipette tip. Mix the tube (by lightly shaking/inverting).
- Using a sterile tip and pipette, transfer 1 mL from the tube labeled 10-1 and transfer to the water blank tube labeled 10-2. Discard the pipette tip. Mix the tube (by lightly shaking/inverting).
- Using a sterile tip and pipette, transfer 1 mL from the tube labeled 10-2 and transfer to the water blank tube labeled 10-3. Discard the pipette tip. Mix the tube (by lightly shaking/inverting).
- Invert the 10-1 test tube to mix, and add 1 mL of the solution to the 1A and 1B petri dishes, respectively.
- Invert the 10-2 test tube to mix, and add 1 mL of the solution to the 2A and 2B petri dishes, respectively.
- Invert the 10-3 test tube to mix, and add 1 mL of the solution to the 3A and 3B petri dishes, respectively.
- Add ~15 mL of melted and cooled agar to each respective petri dish.
- Swirl the plates to properly disperse the sample and allow them to sit for solidification.
- Incubate plates inverted for 48 hours at 37℃.
Aerobic Plate Count Data Analysis: After incubation, quantify the microbial load using the aerobic plate count equation in Image 1. Choose plates that have colonies between 30 – 300 colonies (not TFTC or TNTC). Calculate the aerobic plate count for both trials of the chosen dilution plate to get an average (most accurate).
Why is the aerobic Plate Count Method Used?
The aerobic plate count method is used to quantify the aerobes (oxygen dependent microbes) in a sample. As aerobic bacteria are the most common germs found around homes, workplaces, schools and more, it is an incredibly important laboratory technique.
It is important to remember that aerobic plate count is quantitative, not qualitative. Scientists can further characterize the nature of microorganisms present by using selective and differential media, as well as other techniques.
Ultimately, the aerobic plate count method helps keep people safe. As aerobes cannot be seen with the naked eye, scientists rely on such methods. Aerobic plate count may be used in food science, medical device, healthcare and other industries.
Conclusion

In conclusion, the aerobic plate count method is a necessary laboratory technique. As microbes cannot be seen with the naked human eye, scientists rely on such methods to detect germs in liquid and solid samples.
This microbiology technique may be applied to the food science, medical device, healthcare or pharma industry. As aerobes are one of the most common types of infectious bacteria and enumerate on commonly touched items, its applications are vast.
Ultimately, this microbial testing method helps keep patients and consumers safe.
Subscribe To Our Newsletter For More Free Science Tips!
Next steps
We hope this article has helped you learn more about the Aerobic Plate Count Method. Still have questions? Leave them in the comments and we will do our best to respond!
At My Life Science Career, we are dedicated to being your #1 informational resource for science career and education advice. We are committed to helping scientist build careers they love in a holistic manner. We help our readers by publishing articles on industrial science skills, scholarship/internship postings, career overviews and more.
Want to be a part of our growing, STEM-minded community? Be sure to connect with us on LinkedIn, Twitter, Pinterest and Instagram, where we post daily science career tips!
Similar reads
- Code White Hospital Meaning - November 10, 2026
- Code Pink Hospital Meaning - November 3, 2026
- Code Purple Hospital Meaning - October 27, 2026